H601-K-FRAME-GLASS-FLAT


The Glass T Plate creates a warm and optically transparent surface perfectly flush with the microscope stage. It employs Indium Tin Oxide (ITO) coating to obtain uniform heating throughout the glass surface and a surface sensor to ensure the highest accuracy on temperature reading.
H601-K-FRAME-GLASS-FLAT features anti-scratch, anti-fingerprint, chemically strengthened Dragontrail glass cased in rigid aluminum frame to ensures the highest resistance against breakage and scratches.
Protected by 10 year warranty on glass damage.
It requires H401-T-CONTROLLER or H401-T-PENNY.
Features
- Flush with stages with k-frame insert (160x110mm), compatible with the following XY stage: Marzhauser (all models), Ludl (all models), ASI (all models, including z-piezo), Prior H107 and H117, Leica (k-frame), Zeiss (k-frame), Olympus (k-frame)
- This plate rises the focal plane by 7.5 mm (10 mm for Prior H117).
- Temperature range: from ambient to 60°C
- Accuracy on specimen: ±0.3°C
- ITO glass coating ensures uniform glass heating
- Glass thickness: 0.5 mm
- Aluminum frame improves rigidity
- Anti-scratch, anti-fingerprint, chemically strengthened Dragontrail glass
- 10 year warranty on glass damage
H601-K-FRAME-GLASS-RECESSED

The Glass T Plate creates a warm and optically transparent surface perfectly recessed relative to the stage. It employs Indium Tin Oxide (ITO) coating to obtain uniform heating throughout the glass surface and a surface sensor to ensure the highest accuracy on temperature reading.
H601-K-FRAME-GLASS-RECESSED features anti-scratch, anti-fingerprint, chemically strengthened Dragontrail glass cased in rigid aluminum frame for the highest resistance against breakage and scratches.
Protected by 10 year warranty on glass damage.
It requires H401-T-CONTROLLER or H401-T-PENNY.
Features
- Fits stages with k-frame insert (160x110mm), compatible with the following XY stage: Marzhauser (all models), Ludl (all models), ASI (all models, including z-piezo), Prior H107 and H117, Leica (k-frame), Zeiss (k-frame), Olympus (k-frame)
- Recessed with respect to the rest of the XY stage. Rises the focal plane by only 1.5 mm.
- Temperature range: from ambient to 60°C
- Accuracy on specimen: ±0.3°C
- ITO glass coating ensures uniform glass heating
- Glass thickness: 0.5 mm
- Aluminum frame improves rigidity
- Anti-scratch, anti-fingerprint, chemically strengthened Dragontrail glass
- 10 year warranty on glass damage
H601-K-FRAME-METAL-GLASS

The Glass side of the Metal Glass T Plate creates a warm and optically transparent surface perfectly flush with the microscope stage. It employs Indium Tin Oxide (ITO) coating to obtain uniform heating throughout the glass surface and a surface sensor to ensure the highest accuracy on temperature reading. The glass is chemically strengthened and protected by a rigid aluminum frame.
The metal side of the Metal Glass T Plate features a trimmed 24 mm diameter observation opening for imaging with oil immersion lenses.
The metal and glass sides have independent temperature sensors for independent temperature control of each side.
Protected by 10 year warranty on glass damage.
It requires H401-T-CONTROLLER and uses both control channels (one for the glass and one for the flame).
Features
- Flush with stages with k-frame insert (160x110mm), compatible with the following XY stage: Marzhauser (all models), Ludl (all models), ASI (all models, including z-piezo), Prior H107 and H117, Leica (k-frame), Zeiss (k-frame), Olympus (k-frame)
- Temperature range: from ambient to 60°C
- Accuracy on specimen: ± 0.3°C
- 4.3'' touch screen interface
- On-board data logging and download routines to USB drive
- ITO glass side thickness: 0.5 mm, chemical glass strengthening ensures highest resistance
- Flat respect to the rest of the XY stage
- Uses both channels of the dual controller H401-T-CONTROLLER
- Anti-scratch, anti-fingerprint, chemically strengthened Dragontrail glass
- 10 year warranty on glass damage
H401-K-FRAME-METAL-FLAT

It requires H401-T-CONTROLLER or H401-T-PENNY.
Features
- Flush with stages with k-frame insert (160x110mm); compatible with the following XY stages: Marzhauser (all models), Ludl (all models), ASI (all models, including z-piezo), Prior H107 and H117, Leica (k-frame), Zeiss (k-frame), Olympus (k-frame).
- Flat with respect to the rest of the XY stage.
- This plate rises the focal plane by 7.5 mm (10 mm for Prior H117).
- Temperature range: from ambient to 60°C
- Accuracy on specimen: ± 0.3°C
- Circular observation opening for imaging: 24 mm diameter
- Compatible with oil immersion lenses
- Easy plate replacement, if necessary
H401-K-FRAME-METAL-RECESSED

The Metal T Plate creates a warm temperature controlled surface recessed with the rest of the XY stage to maintain the original focal plane of the XY stage. It employes a surface sensor to ensure the highest accuracy on temperature reading.
It requires H401-T-CONTROLLER or H401-T-PENNY.
Features
- Fits stages with k-frame insert (160x110mm); compatible with the following XY stages: Marzhauser (all models), Ludl (all models), ASI (all models, including z-piezo), Prior H107 and H117, Leica (k-frame), Zeiss (k-frame), Olympus (k-frame).
- Recessed with respect to the rest of the XY stage by: 5.0 mm. This plate rises the focal plane by 2.5 mm.
- Temperature range: from ambient to 60°C
- Accuracy on specimen: ± 0.3°C
- Circular observation opening for imaging: 24 mm diameter