Minimum quantity Discount
Buy 2 + Get 10% discount
Skip to content

Nikon Heating Devices - Stereo Microscopes

Sale price $0.00

SKU: H401-NIKON-SMZ-180-GLASS
Model

Nikon Heating Devices - Stereo Microscopes

This IVF product line comprises Glass and Metal Temperature controlled plates for inverted and stereo microscopes and a centralized CO2/O2 controller to feed mini incubators. 

H401-NIKON-SMZ-180-GLASS

H401-NIKON-SMZ-180_480x320.jpgH401-NIKON-SMZ-180-[DIMENSIONS]420x280.jpg

This ITO glass plate fits in the circular 180 mm opening of the stereo microscope and creates a flat warm surface.

It requires H401-T-CONTROLLER or H401-T-PENNY.

Features

  • T range: ambient to 60°C
  • T sensor accuracy: ±0.1°C
  • T accuracy on specimen: ±0.3°C, after calibration, if room temperature remains within ±1°C
  • Aluminium frame for superior resistance and flatness
  • Glass thickness 2 mm
  • Plate diameter 180 mm

 H401-NIKON-SMZ25-GLASS

H401-NIKON-SMZ25-GLASS_480x320.jpgH401-NIKON-SMZ25-GLASS-[DIMENSIONS]_420x280.JPG

This ITO glass plate fits on the NIKON SMZ25 stereo microscope base and creates a flat warm surface.  

It employs Indium Tin Oxide (ITO) coating to obtain uniform heating throughout the glass surface and a surface sensor to ensure the highest accuracy on temperature reading.

The glass is chemically strengthened and protected by a rigid aluminum frame.

It requires H401-T-CONTROLLER or H401-T-PENNY.

Features

  • Flush with Nikon stereo microscope SMZ
  • Compatible with the following stereo microscope's stand: P2-PB, P2-DBC, P2-DBF, P-PS32, P-DSL32 and P-DSF32
  • Temperature range: from ambient to 60°C
  • Accuracy on specimen: ±0.3°C
  • ITO glass coating ensures uniform glass heating
  • Glass thickness: 1 mm
  • Aluminum frame improves rigidity
  • Chemical glass strengthening ensures highest resistance

H401-NIKON-SMZ25-GLASS/METAL

H401-NIKON-SMZ25-GLASS_METAL_480x320.jpgH401-NIKON-SMZSL-GLASS-[DIMENSIONS]_420x280.jpgH401-NIKON-SMZ25-GLASS-METAL_420x280.jpg

This large metal-glass heater creates a flat heating surface covering the entire stereo microscope stand. The central glass part features Indium Tin Oxide (ITO) coating to obtain uniform heating throughout the glass surface and a surface sensor to ensure the highest accuracy on temperature reading. The wide lateral part features a second surface temperature sensor and a dedicated heating element. Metal and glass surfaces can be independently heated to different temperatures.

It requires H401-T-CONTROLLER and uses both channels (one for the glass and one for the metal)

Features

  • Temperature range: from ambient to 45°C
  • Accuracy: ±0.3°C
  • 4.3'' touch screen controller
  • On-board Data logging and download routines to USB drive
  • Compatible with Nikon stereo microscope SMZ with the following microscope stands: P2-PB, P2-DBC, P2-DBF, P-PS32, P-DSL32 and P-DSF32

 H401-NIKON-SMZSL-GLASS

H401-NIKON-SMZSL-GLASS_480x320.JPGH401-NIKON-SMZSL-GLASS-[DIMENSIONS]_420x280.jpg

This ITO glass plate fits on the NIKON SMZSL stereo microscope base and creates a flat warm surface.
It employs Indium Tin Oxide (ITO) coating to obtain uniform heating throughout the glass surface and a surface sensor to ensure the highest accuracy on temperature reading.

The glass is chemically strengthened and protected by a rigid aluminum frame.

It requires H401-T-CONTROLLER or H401-T-PENNY.

Features

  • Flush with Nikon stereo microscope SMZ 1500/1000/800
  • Compatible with the following stereo microscope's stand: C-DSD, C-DSS, C-BD
  • Temperature range: from ambient to 60°C
  • Accuracy on specimen: ±0.3°C
  • ITO glass coating ensures uniform glass heating
  • Glass thickness: 1 mm
  • Aluminum frame improves rigidity
  • Chemical glass strengthening ensures highest resistance

H401-NIKON-SMZSL-GLASS/METAL

H401-NIKON-SMZSL-GLASS-METAL_480x320.jpgH401-NIKON-SMZ25-GLASS-METAL_420x280.jpg

This large metal-glass heater creates a flat heating surface covering the entire stereo microscope stand. The central glass part features Indium Tin Oxide (ITO) coating to obtain uniform heating throughout the glass surface and a surface sensor to ensure the highest accuracy on temperature reading. The wide lateral part features a second surface temperature sensor and a dedicated heating element. Metal and glass surfaces can be independently heated to different temperatures.

It requires H401-T-CONTROLLER and uses both channels (one for the glass and one for the metal)

Features

  • Temperature range: from ambient to 45°C
  • Accuracy: ±0.3°C
  • 4.3'' touch screen controller
  • On-board Data logging and download routines to USB drive
  • Compatible with Nikon stereo microscope SMZ with the following microscope stands: P2-PB, P2-DBC, P2-DBF, P-PS32, P-DSL32 and P-DSF32

 H401-NIKON-SMZSS-GLASS

H401-NIKON-SMZSS-GLASS_480x320.jpgH401-NIKON-SMZSS-GLASS.jpg

This ITO glass plate fits on the NIKON SMZSS stereo microscope base and creates a flat warm surface. 

It employs Indium Tin Oxide (ITO) coating to obtain uniform heating throughout the glass surface and a surface sensor to ensure the highest accuracy on temperature reading.

The glass is chemically strengthened and protected by a rigid aluminum frame.

It requires H401-T-CONTROLLER or H401-T-PENNY.

Features

  • Flush with Nikon stereo microscope SMZ 1500/1000/800
  • Compatible with the following stereo microscope's stand: C-DS, C-PS
  • Temperature range: from ambient to 60°C
  • Accuracy on specimen: ±0.3°C
  • ITO glass coating ensures uniform glass heating
  • Glass thickness: 1 mm
  • Aluminum frame improves rigidity
  • Chemical glass strengthening ensures highest resistance

H401-NIKON-SMZSS-GLASS/METAL

H401-NIKON-SMZSS-GLASS-METAL_480x320.jpgH401-NIKON-SMZSS-GLASS-METAL_420x280.jpg

This large metal-glass heater creates a flat heating surface covering the entire stereo microscope stand. The central glass part features Indium Tin Oxide (ITO) coating to obtain uniform heating throughout the glass surface and a surface sensor to ensure the highest accuracy on temperature reading. The wide lateral part features a second surface temperature sensor and a dedicated heating element. Metal and glass surfaces can be independently heated to different temperatures.

It requires H401-T-CONTROLLER and uses both channels (one for the glass and one for the metal)

Features

  • Temperature range: from ambient to 45°C
  • Accuracy: ±0.3°C
  • 4.3'' touch screen controller
  • On-board Data logging and download routines to USB drive
  • Compatible with Nikon stereo microscope SMZ 1500/1000/800 with the following microscope stands: C-DS, C-PS

 H401-GLASS TABLE

H401-GLASS-TABLE_480x320.JPGH401-GLASS TABLE-Dimensions(new)-420x280.jpg

The ITO glass table realizes a flat and transparent surface at controlled temperature. Ideal for stereo microscopes. 

It requires H401-T-CONTROLLER or H401-T-PENNY.

Features

  • T range: ambient to 60°C
  • T sensor accuracy: ±0.1°C
  • T accuracy on specimen: ±0.3°C, after self calibration, if room temperature remains within ±1°C
  • 4.3'' touch screen interface
  • On-board data logging and download routines to USB drive
  • Plate calibration can be performed in the lab by the operator
  • Glass thickness: 2 mm
  • Adjustable height:
    • from 31 to 37 mm
    • from 75 to 105 mm

H401-NIKON-NI-S-E-METAL

H401-NIKON-NI-S-E-METAL_480x320.jpgH401-NIKON-NI-S-E-METAL-[DIMENSIONS]_420x280.jpg

The Metal T Plate creates a warm flat temperature controlled surface at the same height as the rest of the XY stage perfectly flush with the microscope stage. 

It employs a surface sensor to ensure the highest accuracy on temperature reading.

It requires H401-T-CONTROLLER or H401-T-PENNY.

Features

  • Fits on Nikon upright microscope Ecplipse with NI-S-E-motorized stage
  • Temperature range: from ambient to 60°C
  • Accuracy on specimen: ± 0.3°C
  • Circular observation opening for imaging: 27 mm diameter
  • Easy plate replacement, if necessary
Back to top