Olympus Heating Devices - Stereo Microscopes
This IVF product line comprises Glass and Metal Temperature controlled plates for inverted and stereo microscopes and a centralized CO2/O2 controller to feed mini incubators.
H401-OLYMPUS-SZX2A-GLASS
This ITO glass plate fits on the Olympus MVX and SZX stereo microscope base and creates a flat warm surface.
It employs Indium Tin Oxide (ITO) coating to obtain uniform heating throughout the glass surface and a surface sensor to ensure the highest accuracy on temperature reading.
The glass is chemically strengthened and protected by a rigid aluminum frame.
It requires H401-T-CONTROLLER or H401-T-PENNY.
Features
- Flush with Olympus stereo microscope MVX and SZX
- Compatible with the following stereo microscope's stand: SZX2-ILLB, SZX2-ILLK, SZX2-ILLD, SXZ2-ST
- Temperature range: from ambient to 60°C
- Accuracy on specimen: ±0.3°C
- 4.3'' touch screen controller
- On-board Data logging and download routines to USB drive
- ITO glass coating ensures uniform glass heating
- Glass thickness: 1 mm
- Aluminum frame improves rigidity
- Chemical glass strengthening ensures highest resistance
H401-OLYMPUS-SZX2A-GLASS/METAL
This large metal-glass heater creates a flat heating surface covering the entire stereo microscope stand. The central glass part features Indium Tin Oxide (ITO) coating to obtain uniform heating throughout the glass surface and a surface sensor to ensure the highest accuracy on temperature reading. The wide lateral part features a second surface temperature sensor and a dedicated heating element. Metal and glass surfaces can be independently heated to different temperatures.
It requires H401-T-CONTROLLER and uses both channels (one for the glass and one for the metal)
Features
- Temperature range: from ambient to 45°C
- Accuracy: ±0.3°C
- 4.3'' touch screen controller
- On-board Data logging and download routines to USB drive
- Compatible with Olympus stereo microscope MVX and SZX with the following microscope stands: SZX2-ILLB, SZX2-ILLK, SZX2-ILLD, SXZ2-ST
H401-OLYMPUS-SZX2B-GLASS

This ITO glass plate fits on the Olympus SZX stereo microscope base and creates a flat warm surface.
It employs Indium Tin Oxide (ITO) coating to obtain uniform heating throughout the glass surface and a surface sensor to ensure the highest accuracy on temperature reading.
The glass is chemically strengthened and protected by a rigid aluminum frame.
It requires H401-T-CONTROLLER or H401-T-PENNY.
Features
- Flush with Olympus stereo microscope MVX and SZX
- Compatible with the following stereo microscope's stand: SZX2-ILLT, SZX2-ILLTS, and SZX2-ILLTQ
- Temperature range: from ambient to 60°C
- Accuracy on specimen: ±0.3°C
- ITO glass coating ensures uniform glass heating
- Glass thickness: 1 mm
- Aluminum frame improves rigidity
- Chemical glass strengthening ensures highest resistance
H401-OLYMPUS-SZX2B-GLASS/METAL

This large metal-glass heater creates a flat heating surface covering the entire stereo microscope stand. The central glass part features Indium Tin Oxide (ITO) coating to obtain uniform heating throughout the glass surface and a surface sensor to ensure the highest accuracy on temperature reading. The wide lateral part features a second surface temperature sensor and a dedicated heating element. Metal and glass surfaces can be independently heated to different temperatures.
It requires H401-T-CONTROLLER and uses both channels (one for the glass and one for the metal)
Features
- Temperature range: from ambient to 45°C
- Accuracy: ±0.3°C
- 4.3'' touch screen controller
- On-board Data logging and download routines to USB drive
- Compatible with Olympus stereo microscope MVX and SZX with the following microscope stands: SZX2-ILLT, SZX2-ILLTQ, and SZX2-ILLTS
H401-GLASS TABLE
The ITO glass table realizes a flat and transparent surface at controlled temperature. Ideal for stereo microscopes.
It requires H401-T-CONTROLLER or H401-T-PENNY.
Features
- T range: ambient to 60°C
- T sensor accuracy: ±0.1°C
- T accuracy on specimen: ±0.3°C, after self calibration, if room temperature remains within ±1°C
- 4.3'' touch screen interface
- On-board data logging and download routines to USB drive
- Plate calibration can be performed in the lab by the operator
- Glass thickness: 2 mm
- Adjustable height:
- from 31 to 37 mm
- from 75 to 105 mm