Olympus Heating Devices - Inverted Microscopes
This IVF product line comprises Glass and Metal Temperature controlled plates for inverted and stereo microscopes and a centralized CO2/O2 controller to feed mini incubators.
H601-OLYMPUS-IX-SUSP-GLASS


The Glass T Plate creates a warm and optically transparent surface perfectly flush with the microscope stage. It employs Indium Tin Oxide (ITO) coating to obtain uniform heating throughout the glass surface and a surface sensor to ensure the highest accuracy on temperature reading.
H601-OLYMPUS-IX-SUSP-GLASS features anti-scratch, anti-fingerprint, chemically strengthened Dragontrail glass cased in rigid aluminum frame to ensures the highest resistance against breakage and scratches.
Protected by 10 year warranty on glass damage.
It requires H401-T-CONTROLLER or H401-T-PENNY.
Features
- Flush with Olympus stages: IX-SUSP, GX-SVR, GX-SFR, BX3-SSU, IX2-SFR, IX2-SVL-2
- Temperature range: from ambient to 60°C
- Accuracy on specimen: ±0.3°C
- ITO glass coating ensures uniform glass heating
- Glass thickness: 0.5 mm
- Aluminum frame improves rigidity
- Anti-scratch, anti-fingerprint, chemically strengthened Dragontrail glass
- 10 year warranty on glass damage
H601-OLYMPUS-IX-SUSP-GLASS/FRAME


H601-OLYMPUS-IX-SUSP-GLASS/FRAME is a dual channel plate featuring Indium Tin Oxide (ITO) coated glass cased in a heated aluminium frame.
It provides a warm and optically transparent surface perfectly flush with the microscope stage with the best possible temperature uniformity and accuracy, achieved by controlling the temperature of both the glass and the metal frame.
H601-OLYMPUS-IX-SUSP-GLASS/FRAME features anti-scratch, anti-fingerprint, chemically strengthened Dragontrail glass cased in rigid aluminum frame to ensures the highest resistance against breakage and scratches.
Protected by 10 year warranty on glass damage.
It requires H401-T-CONTROLLER and uses both control channels (one for the glass and one for the flame).
Features
- Flush with Olympus stages: IX-SUSP, GX-SVR, GX-SFR, BX3-SSU, IX2-SFR, IX2-SVL-2
- Dual channel: heated Glass and heated Metal Frame
- Temperature range: from ambient to 60°C
- Accuracy on specimen: ±0.3°C
- ITO glass coating ensures uniform glass heating
- Glass thickness: 0.5 mm
- Aluminum frame improves rigidity
- Anti-scratch, anti-fingerprint, chemically strengthened Dragontrail glass
- 10 year warranty on glass damage
H401-OLYMPUS-IX-SUSP-METAL


The Metal T Plate creates a warm flat temperature controlled surface perfectly flush with the microscope stage and features a circular observation opening in the center. It employs a surface sensor to ensure the highest accuracy on temperature reading.
It requires H401-T-CONTROLLER or H401-T-PENNY.
Features
- Flush with Olympus stages: IX-SUSP, GX-SVR, GX-SFR, BX3-SSU, IX2-SFR, IX2-SVL-2
- Temperature range: from ambient to 60°C
- Accuracy on specimen: ± 0.3°C
- Circular observation opening for imaging: 24 mm diameter
- Easy plate replacement, if necessary
H401-OLYMPUS-IX-SUSP-T-PAD

The Stage Heater covers the entire GX-SFR and IX2-SFR Olympus stages and provides a flat, smooth surface at controlled temperature. It clamps on the stage and it is fixed in place by set crews positioned on the vertical sides of the plate. The Stage Heater leaves the observation hole open.
It is possible and recommendable to use the Stage Heater in combination with Glass Heated Insert. In this configuration, the H401-T-CONTROLLER uses one channel to control the metal PAD and the other channel to control the Glass Insert. Models available for Nikon and Olympus stages.
Recommended controller: H401-T-CONTROLLER.
Features
- Clamps on the GX-SFR and IX2-SFR Olympus stages and creates a flat surface at constant T
- Temperature range: from ambient to 45°C
- Accuracy: ±0.3°C
- 4.3'' touch screen controller
- On-board Data logging and download routines to USB drive
- Compatible with Glass Plates
- Easy to fix on stage
H601-OLYMPUS-IX3-SVR-GLASS/FRAME


H601-OLYMPUS-IX3-SVR-GLASS/FRAME is a dual channel plate featuring Indium Tin Oxide (ITO) coated glass cased in a heated aluminium frame.
It provides a warm and optically transparent surface perfectly flush with the microscope stage with the best possible temperature uniformity and accuracy, achieved by controlling the temperature of both the glass and the metal frame.
H601-OLYMPUS-IX3-SVR-GLASS/FRAME features anti-scratch, anti-fingerprint, chemically strengthened Dragontrail glass cased in rigid aluminum frame to ensures the highest resistance against breakage and scratches.
Protected by 10 year warranty on glass damage.
It requires H401-T-CONTROLLER and uses both control channels (one for the glass and one for the flame).
Features
- Compatible with the following XY stages: Olympus IX3-SVR, IX3-SVL and IX3-SSU
- Dimensions of heated glass: 119x87 mm
- Dual channel: heated Glass and heated Metal Frame
- Temperature range: from ambient to 60°C
- Accuracy on specimen: ±0.3°C
- ITO glass coating ensures uniform glass heating
- Glass thickness: 0.5 mm
- Aluminum frame improves rigidity
- Anti-scratch, anti-fingerprint, chemically strengthened Dragontrail glass
- 10 year warranty on glass damage
- Requires H401-T-CONTROLLER, uses both channels



