{"product_id":"okolab-h601-heated-glass-stage-inserts-for-inverted-microscopes-nikon-olympus-leica","title":"Okolab H601 Heated Glass Stage Inserts for Inverted Microscopes (Nikon, Olympus, Leica)","description":"\u003ch2\u003e\u003cb\u003eOkolab H601 Heated Glass Stage Inserts for Inverted Microscopes (Nikon, Olympus, Leica)\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp\u003eOkolab heated glass plates for inverted microscopes provide excellent thermal stability and optical clarity during delicate embryo observation and manipulation processes, including ICSI and laser-assisted oocyte hatching.\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eDesign ensures that glass plates are perfectly flush with the microscope stage. Includes an Indium Tin Oxide (ITO) coating to obtain uniform heating throughout the glass. An integrated surface sensor ensures the highest thermal accuracy in the specimen.\u003c\/p\u003e\n\u003cp\u003eAll H601- series plates feature anti-scratch, anti-fingerprint, chemically strengthened Dragontrail glass, encased in a rigid aluminum frame; these qualities ensure superior flatness and provide resistance against breakage and glass scratches. \u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eWarranty:\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e2-year full manufacturer’s warranty from shipping date.\u003cbr\u003e10-year warranty on glass damage for all H601- series products.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eHeated glass stage inserts include our compact single-channel H401-T-PENNY temperature controller.\u003cspan class=\"Apple-converted-space\"\u003e  \u003c\/span\u003e\u003c\/b\u003eH401-T-PENNY combines high performance and simplicity at an affordable price.\u003c\/p\u003e\n\u003cp\u003eA trusted manufacturer since 2002, Okolab supplies top-quality, thoughtfully designed environmental control solutions to IVF facilities worldwide.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eFEATURES\u003c\/b\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eH401-T-PENNY Temperature Controller:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eT range: ambient to 60°C\u003c\/li\u003e\n\u003cli\u003eT sensor accuracy: ±0.1°C\u003c\/li\u003e\n\u003cli\u003eT accuracy on specimen: ±0.3°C after calibration, if room temperature remains within ±1°C\u003c\/li\u003e\n\u003cli\u003eEasy one-point temperature offset calibration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2245\/7875\/files\/H401-T-PENNY_alternateview-2.jpg?v=1770393710\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eH601-NIKON-TI-SR-GLASS:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCompatible with stage models: T\/Ti-SR, Ti-SP\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eGlass thickness: 0.5mm\u003c\/li\u003e\n\u003cli\u003eDimension: φ108\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2245\/7875\/files\/H601-NIKON-TI-SR-GLASS_dimension.jpg?v=1771854357\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eH601-NIKON-TS2R-GLASS:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCompatible with stage models: TC-S-SR, TC-S-SRF, and TS2-S-SM; also compatible with any XY stage equipped with a holder for standard multiwell plates (128x86 mm)\u003c\/li\u003e\n\u003cli\u003eGlass thickness: 0.5mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2245\/7875\/files\/H601-NIKON-TS2R-GLASS.jpg?v=1771854356\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eH601-OLYMPUS-IX-SUSP-GLASS:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCompatible with stage models: IX-SUSP, GX-SVR, GX-SFR, BX3-SSU, IX2-SFR, IX2-SVL-2\u003c\/li\u003e\n\u003cli\u003eGlass thickness: 0.5mm\u003c\/li\u003e\n\u003cli\u003eDimension: φ110\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2245\/7875\/files\/H601-OLYMPUS-IX-SUSP-GLASS_dimension.jpg?v=1771854356\" alt=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eH601-LEICA-R88-GLASS:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCompatible with stage models: manual 3-plate stage with 88mm circular opening\u003c\/li\u003e\n\u003cli\u003eGlass thickness: 0.5mm\u003c\/li\u003e\n\u003cli\u003eDimension: φ88\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/2245\/7875\/files\/H601-LEICA-R88-GLASS_dimensions.jpg?v=1771854356\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eComponents:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eH401-T-PENNY temperature controller with detachable inclined magnetic base\u003cbr\u003ePower supply with replaceable power cord\u003cbr\u003eHeated plate of your choice\u003cbr\u003eUser manual\u003c\/p\u003e","brand":"Okolab","offers":[{"title":"1 EA \/ H601-OLYMPUS-IX-SUSP-GLASS","offer_id":47693344997614,"sku":"BUNDLE-H601-OLYMPUS-IX-SUSP-GLASS\/PENNY","price":2400.0,"currency_code":"USD","in_stock":true},{"title":"1 EA \/ H601-NIKON-TI-SR-GLASS","offer_id":47693345030382,"sku":"BUNDLE-H601-NIKON-TI-SR-GLASS\/PENNY","price":2400.0,"currency_code":"USD","in_stock":true},{"title":"1 EA \/ H601-NIKON-TS2R-GLASS","offer_id":47693345063150,"sku":"BUNDLE-H601-NIKON-TS2R-GLASS\/PENNY","price":2550.0,"currency_code":"USD","in_stock":true},{"title":"1 EA \/ H601-LEICA-R88-GLASS","offer_id":47693345095918,"sku":"BUNDLE-H601-LEICA-R88-GLASS\/PENNY","price":2400.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2245\/7875\/files\/H601-LEICA-R88-GLASS_a92070f3-7d40-4b8b-842a-27a240c43e0d.jpg?v=1771854964","url":"https:\/\/us.ivfstore.com\/products\/okolab-h601-heated-glass-stage-inserts-for-inverted-microscopes-nikon-olympus-leica","provider":"IVF Store","version":"1.0","type":"link"}